DP flow elements

Compact Orifice Plate Flowmeter For Differential Pressure

Integral DP flow meter for liquids, gases and steam

Features

  • Fast and easy installation without additional engineering, impulse lines or supports
  • Up to +400°C / +752°F; max. 160 bar / 2320 psi (line pressure)
  • Line size: DN50…600 / 2…24″
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

Averaging Pitot Tube Flowmeter For Differential Pressure

DP flow meter for applications with liquids, gases and steam to high-temperature applications with dust-laden gases

Features

  • Fast and easy installation without additional engineering, impulse lines and supports; the best retrofit capability
  • -200…+1150°C / -328…2102°F; max. 320 bar / 4641.2 psi (line pressure)
  • For line sizes DN50…2000 / 2…80″ (larger on request)
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

Flow Nozzle Meter For Differential Pressure

DP flow meter for long-term stable flow measurement with reduced pressure loss

Features

  • Based on ISA 1932, long radius or Venturi nozzle (acc. to ISO 5167-3 or ASME MFC-3M)
  • Accurate flow measurement at high flow velocities (e.g. feed water, steam, condensate, hydrocarbons, refined products, CO2, LH2)
  • Manufacturing capability up to 48”; inhouse calibration also for applications with high Reynolds numbers
  • Complete scope of supply from one source, including engineering, documentation, testing, calibration, valves, flow nozzle, process instrumentation, etc.

Integral Orifice Meter Run Assembly For Differential Pressure

DP flow meter for process applications with small line sizes (down to DN15 / ½”)

Features

  • Standardised calibrated meter run assembly, designed acc. to ISO 5167 or ISO TR 15377
  • Up to +400°C / +752°F; max. 160 bar / 2320 psi (line pressure)
  • Flange: DN15…100 / ½…4″
  • 2-wire, 4…20 mA/HART®, FF, Profibus-PA