Electromagnetic Flow Meter

Optiflux AFE400 Electromagnetic Flow Meter

Electromagnetic flowmeter for utilities and industrial automation.
Features
  • Flow measurement of conductive liquids, e.g. coolants, cold/hot water, chemicals, etc.
  • Best-in class temperature range, accuracy, pressure drop and flow range
  • Ultra-compact design for parallel installation and tight spaces
  • 4…20 mA, pulse, frequency, Modbus, IO-Link

Optiflux 1050/1100/1300 Electromagnetic Flow Meters for Conductive Fluids

Electromagnetic flowmeters for basic applications with conductive liquids
Features
  • Cost-effective flow measurement of liquids (≥5 μS/cm) up to +120°C / +248°F
  • Extra isolation of electronics for use in high humidity areas
  • Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

Optiflux 2050/2100/2300 Electromagnetic Flow Meters for Water Applications

Optiflux 2050

Electromagnetic flowmeter for basic water and wastewater applications
Features
  • Liner materials resistant to low concentrated chemicals
  • With extra isolation of electronics for use in high humidity areas
  • Flange: DN25…1200 / 1…48", max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

Optiflux 2100 

Electromagnetic flowmeter for all standard water and wastewater applications
Features
  • Chemically resistant liner materials
  • Compact version up to IP69, remote version IP68
  • Flange: DN25…1200 / 1…48", max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®
Optiflux 2300
Electromagnetic flow meter for advanced water and wastewater applications Features
  • High accuracy (±0.2%), with CT approvals (OIML R49, MI-001)
  • 0D/0D installation acc. to MID MI-001 and OIML R49 accuracy class 1
  • Flange: DN25…3000 / 1…120", max. PN40 / ASME Cl 300
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

Waterflux 3070 Battery Powered Electromagnetic Flow Meter for Water Application

Electromagnetic water meter for district metering of potable water and custody transfer (CT) measurement
Features
  • Battery or mains powered, with battery backup option (incl. Modbus)
  • Integrated temperature and pressure measurement for leak monitoring
  • CT: MI-001, OIML R49 up to DN600 / 24", no inlet/outlet runs needed
  • Burial installation possible (IP68)
 

Optiflux 4050/4100/4300 Electromagnetic Flow Meters for Chemicals and Slurries

Optiflux 4050

Electromagnetic flow meter for basic applications with abrasive and aggressive liquids
Features
  • Chemically resistant liner materials
  • With extra isolation of electronics for use in high humidity areas
  • Flange: DN2.5…1200 / ⅒…48", max. PN40 / ASME Cl 600
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

Optiflux 4100

Electromagnetic flow meter for standard applications with abrasive and aggressive liquids
Features
  • Chemically resistant, for liquids (>5 μS/cm) with solid content (≤10%)
  • Up to +180°C / +356°F
  • Flange: DN2.5…1200 / ⅒…48", max. PN40 / ASME Cl 600
  • 4…20 mA, pulse, frequency, status, HART®

Optiflux 4300

Electromagnetic flow meter for advanced process and custody transfer (CT) applications
Features
  • High accuracy (±0.2%), certified for custody transfer
  • For low conductivity media (>1 μS/cm) and high solid contents (≤70%)
  • Flange: DN2.5…3000 / ⅒…120", max. PN40 / ASME Cl 600
  • 3 x 4…20 mA, HART®,Modbus, FF, Profibus-PA/DP, PROFINET

Optiflux 5050/5100/5300 Ceramic Electromagnetic Flow Meters for Conductive Liquids and Slurries

Optiflux 5100

Electromagnetic flow meter for demanding applications with aggressive and abrasive media
Features
  • With chemically resistant ceramic tube for liquids with solid content (≤10%)
  • Up to +180°C / +356°F
  • Flange: DN15…300 / ½…12", max. PN40 / ASME Cl 300; Sandwich: DN2.5...100 / ⅒...4"
  • 4…20 mA, pulse, frequency, status, HART®
 

Optiflux5300

Electromagnetic flow meter for advanced process and master meter applications
Features
  • Highest accuracy (±0.15%), with ceramic tube for aggressive and abrasive liquids (≤70% solid content) up to +180°C / +356°F
  • CT: OIML R117, MI-005 etc.
  • Flange: DN15…300 / ½…12", max. PN40 / ASME Cl 300; Sandwich: DN2.5...100 / ⅒...4"
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

Optiflux 6050/6100/6300 Electromagnetic Flow Meters for Hygienic Applications in Food and Pharmaceutical Industry

Optiflux6050:

Electromagnetic flow meter for basic hygienic applications
Features
  • Cost-effective flow measurement in the food sector
  • Meter size: DN2.5…150 / ⅒…6" (EHEDG etc.)
  • Many hygienic fittings
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

Optiflux6100:

Electromagnetic flow meter for hygienic standard applications
Features
  • Reliable dosing and filling in the food sector
  • Meter size: DN2.5…150 / ⅒…6"
  • Hygienic fittings and certifications
  • 4…20 mA, pulse, frequency, status, HART®

Optiflux6300:

Electromagnetic flow meter for advanced hygienic applications
Features
  • High accuracy (±0.2%), for exact dosing or filling in the food sector
  • Meter size: DN2.5…150 / ⅒…6" (3A, EHEDG certified)
  • Many hygienic fittings
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

Optiflux 6300 Electromagnetic Flow Meter

Electromagnetic flow meter for advanced hygienic applications

Features

  • High accuracy (±0.2%), for exact dosing or filling in the food sector
  • Meter size: DN2.5…150 / ⅒…6" (3A, EHEDG certified)
  • Many hygienic fittings